View online (9 pages) or download PDF (383 KB) National Instruments TB-2725 Installation manual • TB-2725 PDF manual download and more National Instruments online manualsSCXI-1320 Installation Guide 4 ni. 75 m 185440-0R75 Matrix expansion Use with the SCXI-1333,SCXI-1334, SCXI-1335, and 778364-01 plug (Figure 8) SCXI-1336 to connect the columns of adjacent terminal blocks. With its 128 connectors, the matrix expansion plug. 5500. 7. The terminal block has 48 screw terminals for easy signal connections. SCXI-1129 SCXI-1333 – Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrix SCXI-1334 – Configures SCXI-1129 as 4 x 64 (2-wire) matrixSCXI ™ SCXI-1129 User Manual 256 Crosspoint High-Density Matrix SCXI-1129 User Manual February 2001 Edition Part Number 322740A-01 Support Worldwide Technical Support and Product Information ni. NI voltage input module SCXI-1104C 32 Differential channel chassis. Relay Module. NI SCXI-1333 Terminal BlockThe SCXI-1333 by National Instruments (Item Number: 777687-33) is a flexible terminal block that allows the user to access all row and column connections. Please call or email us with your request. 778364-01 Cables SH68-68S The SCXI-1161 (Part Number: 776572-61) is an 8-Channel General-Purpose Switch Module with individual single-pole double-throw (SPDT) (Form C), latching relays. If you need a specific configuration please contact Artisan Sales. Find the National Instruments SCXI-1324 at our website: Click HERE. Leave jumper W1 on the SCXI-1100 in the factory-default (parking) position. Member. 295361 × 10–3, b = 2. 8 x 17. Order toll free: 800. SCXI-1127. Do not loosen or re-orient the safety-ground lug hardware when connecting the safety ground wire; to do so reduces the safety isolation between the high voltage and safetyThe NI SCXI-1163 (Part Number: 776572-63) is an isolated Digital Output Module. Select a unique address for each chassis in the system. With this Terminal Block, the user can configure the SCXI-1129 as a 2-wire, dual 4 by 32 matrix. Bold text also denotes parameter names. Refer to the following tables to determine how the circuit board corresponds to the wiring guide. (DAQ) device and two SCXI modules. SCXI-1160 SCXI-1324 48 screw terminal 777687-24 SCXI-1161 TBX-24F 24 screw terminals 777276-01 SCXI-1163R SCXI-1326 48 screw terminal 777687-26 TBX-1326 48 screw terminal Din. Page 9: Electromagnetic Compatibility The following is a comprehensive list of all National Instruments part numbers that were made End-of-Life (EOL) in late 2016 in an effort to ensure compliance with the RoHS directive. We use SCXI 1320 to get measurements for voltages and SCXI1303 to get measurements for temperatures. NI SCXI-1129 SCXI-1333 Quad 4x16 External wires With matrix expansion plug. All specifications are subject to change without notice. We have 1 National Instruments SCXI-1333 manual available for free PDF download: User Manual . 5-Slot, Integrated Remote Controller PXI Chassis —The PXI‑1033 is designed for remote control applications. The SCXI-1000 and SCXI-1000DC hold up to four modules. Many products are not available yet. Table 1. Leave jumper W1 on the SCXI-1100 in the factory-default (parking) position. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politicsSCXI-1120 SCXI-1305 – BNC connectors, AC/DC coupling and ground referencing SCXI-1120D SCXI-1320 – SCXI-1126 SCXI-1327 Extends signal input range to 300 Vrms, switch configurable per channel SCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1338 Current input, 249 Ω resistor across each inputNI SCXI -1333 Terminal Block for the NI SCXI-1129 This guide describes how to install and connect signals to the National Instruments SCXI-1333 terminal block to configure the SCXI-1129 switch module as a quad 4× 16 matrix. Compliance Electromagnetic Compatibility Information This hardware has been tested and found to comply with the applicable regulatory requirements and limitsPXI-1033. Perform another verification to ensure that the SCXI-1600 is operatingSCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-0104-23-2009 11:51 AM. To detect Metal Work Safe Air 70 series Control Unit PDF Operating Instructions (Updated: Sunday 21st of May 2023 02:00:30 AM) Rating: 4. 0. Refer to the following tables to determine how the circuit board corresponds to the wiring guide. com Figure 4. SCXI-1128 SCXI-1332 – Set up an 8 column by 4 row matrix SCXI-1129 SCXI-1333 – Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrix SCXI-1334 – Configures SCXI-1129 as 4 x 64 (2-wire) matrix SCXI-1335 – Configures SCXI-1129 as 8 x 32 (2-wire) matrix SCXI-1336 – Configures SCXI-1129 as 16 x 16 (2-wire) matrix Accessories Available for the NI SCXI-1129 Accessory Part Number NI SCXI-1333 terminal block (quad 4 × 16, 2-wire matrix) 777687-33 NI SCXI-1334 terminal block (4 × 64, 2-wire matrix) 777687-34 NI SCXI-1335 terminal block (8 × 32, 2-wire matrix) 777687-35 NI SCXI-1336 terminal block (16 × 16, 2-wire matrix) (dual 8 × 16, 2-wire matrix. Figure 1 shows the SCXI-1325 terminal block parts locator diagram. SCXI. Find more compatible user manuals for 258 Series Control Unit device. To replace the main power fuse, follow these instructions: Power off the chassis. Figure 1. Overview. SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. com ¥ ni. NI is committed to producing environmentally friendly products as part of the NI Hazardous Substance Reduction initiative, a voluntary program modeled after the EU Directive on Restriction of the Use of Certain Hazardous Substances (RoHS). Whether you need to measure sensors or raw signals, generate voltages or currents, monitor digital lines, or route signals with switching, SCXI provides a single, integrated. Begin with all three SCXI chassis powered off and unplugged. 8-Channel, General-Purpose Switch Module for SCXI —The SCXI‑1161 is a general-purpose switching module with independent single‑pole double‑throw (SPDT), also called Form C, latching relays with very low on-resistance and low thermal offset. SCXI-1333 NI module SCXI-1333 NI module Module Clips Drive controller servo motor Contact: Mr. Spring. The SH1006868. Because of the general-purpose nature of this terminal block, you can combine the rows and/or columns to create many different matrix configurations. NI SCXI-1337 terminal block (dual 4 × 32, 2-wire matrix) 777687-37 NI SCXI-1339 terminal block 777687-39 Matrix expansion plug 778364-01 0. NATIONAL INSTRUMENTS NI-SCXI-1327. Connect the handshaking lines from the front of either the SCXI-1333, SCXI-1334, SCXI-1335, SCXI-1336, SCXI-1337, or SCXI-1339 terminal block to the appropriate lines on the external DMM. Page 58: Wire Ored National Instruments SCXI-1332 Matrix Terminal Block- for use with the SCXI-1127 and SCXI-1128: In Stock Ships Today: SCXI-1333: National Instruments SCXI-1333 Terminal Block- used with SCXI-1129: Call: SCXI-1334: National Instruments SCXI-1334- configures the SCXI-1129 as a 4 x 64, 2-wire matrix: In Stock Ships Today: SCXI-1335 The SCXI-1333 configures the SCXI-1129 as four separate 4 × 16 matrices. Up to 50% Off MSRP. . pgoguen. You can request repair, RMA, schedule calibration, or get technical support. 3. Includes: Adapter and installation guide. More National Instruments Manuals . com Data Acquisition and Signal Conditioning Overview Na tional Instruments SCXI terminal blocks provide a convenientSCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. 32-channel high-voltage multiplexer/matrix module (44 pages). National Instruments SCXI Products. This moduleControl Unit NI SCXI-1333 Installation Instructions Manual. Introduction The SCXI-1353 makes a low-noise, long-distance connection between a 100-pin E Series DAQ device and two SCXI modules. This versatile component can combine rows and columns to establish a variety of network layouts. The terminals labeled GND are not used on the SCXI-1162. This General-Purpose Terminal Block is designed for signal conditioning and cold-junction compensation. Ensure the modules are setup properly in the Modules tab to match the physical configuration of the chassis. SCXI -1333/1334/1336/1339 WIRING MAPS The terminal names on the circuit board differ from those on the wiring guide located on the underside of the terminal block lid. TBX-1303 32-Channel Isothermal Terminal Block Installation GuideGet a quote for a Used SCXI 1129 Multiplexers from Apex Waves, LLC at used-line. The SCXI kit connects. Before beginning the SCXI configuration. In most applications, this is the most convenient grounding option. SCXI-1314 Shunt-Calibration Resistors and Quarter-Bridge Resistors R1 RPJ R2 R3 UJ SCB SCB SCB SCB SCA SCA SCA SCA QTR QTR. com Do not loosen or re-orient the safety-ground lug hardware when connecting the safety-ground wire; to do so reduces the safety isolation between the high voltage and safety ground. Note; All products of this site are special products, the market price has been fluctuating, specific customer service quotation shall prevail, because the product is a new product, the picture is notThe SCXI-1304 AC/DC is a shielded terminal block with screw terminals that you can connect to the SCXI-1140, SCXI-1141/1142/1143, SCXI-1120/D, SCXI-1125, or SCXI-1126 input connector. NI SCXI-1104C 32通道 National Instruments SCXI1104C 板卡NI SCXI-1104C 数据采集卡 32通道32通道,60 VDC,10 kHz 滤波器,用于SCXI的电压输入模块 - SCXI‑1104C专为高电压信号的信号调理而设计。 它具有一个10 kHz截止频率滤波器。 所有通道可多路复用控制DAQ设备的单个通道,从而增加了DAQ系统的通道数。Control Unit NI SCXI‑1127 User Manual. National Instruments. The function of the SCXI-1303 is to minimise errors caused by thermogradients whereas the function of the SCXI-1300 is for cold junction compensation. Models . Hi, I have a SCXI-1303, on an SCXI-1102C on an SCXI 1000 chassis. Spring. SCXI -1333/1334/1336/1339 WIRING MAPS The terminal names on the circuit board differ from those on the wiring guide located on the underside of the terminal block lid. SCXI-1100 modules. 777687-33 National Instruments national instruments 777687-33 scxi-1333 terminal block to configure scxi-1129 as quad 4x16 (2-wire) matrixTerminal Block Compatible SCXI Modules Cabling CJC Special Features TBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-964 Open TC detection isothermal construction, selectable ground referencing TBX-1316 SCXI-1120/D, SCXI-1125, SCXI-1126 SH32-32-A Ð 200:1 attenuation (up to 1,000 VDC)Control Unit NI SCXI-1333 Installation Instructions Manual. These resistors are placed in sockets onConventions The following conventions are used in this manual: <> Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name—for example,7. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. You can easily and quickly expand your switch system with these plugs. SCXI chassis SCXI-1102/B/C or SCXI-1100 module One package of four 10 Ω resistor networks Number 1 and 2 Phillips-head screwdrivers 1/10 in. The device weighs 14 oz. The following is a comprehensive list of all National Instruments part numbers that were made End-of-Life. Up to 50% Off MSRP. Because of the general-purpose nature of this terminal block, you. com ¥ ni. NI SCXI-1129 256-Crosspoint Relay Matrix This document lists specifications for the NI SCXI-1129 matrix module. You can use the SCXI-1333 with the SCXI-1129 to create four, 4 × 16 matrices. Reinstall the strain-relief bar and tighten the strain-relief screws. The SCXI-1180 and SCXI-1181 are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Terminal block (8 pages) Control Unit NI SPEEDY-33 Installation Manual. Home Support Documentation Dimensional Drawings SCXI-1333 Dimensional Drawings SCXI-1333 Dimensional Drawings This page provides dimensional drawings for the. This page provides dimensional drawings for the SCXI-1333. 777687-01 Summary: 777687-01 from National Instruments is National Instruments 777687-01 SCXI-1301 SCREW TERMINAL BLOCK CAST Details. SCXI-1333 Data acquisition card, NI, SCXI-1333 Data acquisition card Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States SCXI-1314 Printed Circuit Board Diagram The following illustration shows the locations of the SCA and SCB resistors, the quarter-bridge resistors, and channels 0 through 7 of the SCXI-1314 terminal block. The SCXI main power fuse is located next to the voltage selection wheel on the back of the chassis. 4350. Free Ground Shipping. Within the SCXI chassis, identify the appropriate SCXI module to connect to the cable adapter. Examples: 4x128, 4x256 With matrix expansion plug. and lists the device specifications. NI SCXI-1333: Quad 4×16: No: Yes, with matrix expansion plug. This page provides dimensional drawings for the SCXI-1333. SCXI-1346 Shielded Multichassis Cable Adapter 2 ni. A. The SCXI-1120 and SCXI-1120D are National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) Series modules. Other than AC/DC Coupling, this model also has BNC connectors and signal ground referencing which can be. Brand: National. Model. Samsung, Hynix and Micron make the DRAM and assemble modules. SCXI-1120 SCXI-1305 – BNC connectors, AC/DC coupling and ground referencing SCXI-1120D SCXI-1320 – SCXI-1126 SCXI-1327 Extends signal input range to 300 Vrms, switch configurable per channel SCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1338 Current input, 249 Ω resistor across each inputPhone: (217) 352-9330. computer to an SCXI switch module. More NI Manuals . Leave jumper W1 on the SCXI-1100 in the factory-default (parking) NI SCXI-1129 256-Crosspoint Relay Matrix This document lists specifications for the NI SCXI-1129 matrix module. All specifications are subject to change. SCXI-1327 Installation Guide 2 ni. 435 Series . pdf file (23 Mar 2023) Manufacturer: National Instruments; Category of Device: Matrix Switcher;NI SCXI-1333 Installation Instructions 2 ni. The SCXI-1353 consists of an SH1006868 cable, an SCXI-1349 shielded cable adapter, and an AI-48/DIO-24 adapter. Options. The module to the right of the one directly connected to the SCXI-1346 cannot have an external cable inserted into its rear 50-pin connector. Ensure the DAQ (Data AQuisition) device used to connect to SCXI Chassis is recognized by NI-MAX and self-test has passed succesfully. The matrix expansion plugs expand the row count of the following SCXI-1129 terminal blocks: SCXI-1333, SCXI-1334, SCXI-1335, and SCXI-1336. Complies with the essential requirements of the following applicable European Directives: Electromagnetic Compatibility (EMC) Directive 2014/30/EU,Re: Bad readings using SCXI 1102 and TBX 1303. • Ground the negative lead of the thermocouple inside the SCXI-1300 terminal block, by connecting CH– to CHSGND as shown in Figure 4. You can use the SCXI-1333 with the SCXI-1129 to create four, 4 × 16 matrices. Reinstall the top cover and tighten the top cover screws. The SCXI-1163 has the capability to interface to field digital logic signals, removing ground-loop issues and segregating the host computer. This page provides dimensional drawings for the SCXI-1333. National Instruments SCXI-1349 Adapter Board. Abstract: SCXI-1100 SCXI-1102 Text: -1326 TBX-1303 TBX- 24F The TBX-1303 (Figure 2) is a terminal CB-50 block for use with the SCXI-1100, * The TBX- 24F is a general-purpose feedthrough terminal block that can be used with any SCXI module , Terminal Blocks Figure 1. Refer to the following tables to determine how the circuit board corresponds to the wiring guide. Phone: (217) 352-9330. com Data Acquisition and Signal Conditioning Overview Na tional Instruments SCXI terminal blocks provide a convenientNI SCXI-1331 Installation Instructions 8 ni. You can visually inspect the fuse to determine if it is blown. SCXI-1128 SCXI-1332 Ð Set up an 8 column by 4 row matrix SCXI-1129 SCXI-1333 Ð Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrix SCXI-1334 Ð Configures SCXI-1129 as 4 x 64 (2-wire) matrix SCXI-1335 Ð Configures SCXI-1129 as 8 x 32 (2-wire) matrix SCXI-1336 Ð Configures SCXI-1129 as 16 x 16 (2-wire) matrix SCXI-1129 SCXI-1333 – Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrix SCXI-1334 – Configures SCXI-1129 as 4 x 64 (2-wire) matrix SCXI-1335 – Configures SCXI-1129 as 8 x 32 (2-wire) matrix SCXI-1336 – Configures SCXI-1129 as 16 x 16 (2-wire) matrix SCXI-1337 – Configures SCXI-1129 as a dual 8 x 16 (2-wire) matrix Matrix expansion Use with the SCXI-1333,SCXI-1334, SCXI-1335, and 778364-01 plug (Figure 8) SCXI-1336 to connect the columns of adjacent terminal blocks. SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. Please. Install the SCXI modules into the chassis—refer to your module/chassis documentation for instructions. SCXI-1160 SCXI-1324 48. manualslib. SCXI-1302 for the appropriate module, as indicated in Figure 2. SCXI-1333 Board to Guide Map Circuit Board Markings Wiring Guide. The terminal block works with the use of matrix expansion plugs for instant row expansion via column connection and requires no. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100. Connecting two SCXI-1333 terminal blocks as described above creates four separate 8 × 16 matrices. 75 m 185440-0R75 Matrix expansion Use with the SCXI-1333,SCXI-1334, SCXI-1335, and 778364-01 plug (Figure 8) SCXI-1336 to connect the columns of adjacent terminal blocks. One Year Warranty. 5 V) affect the channel data for all channels. Abstract: SCXI-1100 SCXI-1102 Text: -1326 TBX-1303 TBX-24F The TBX-1303 (Figure 2) is a terminal CB-50 block for use with the SCXI-1100, * The TBX-24F is a general-purpose feedthrough terminal block that can be used with any SCXI module , Terminal Blocks Figure 1. Examples: quad 8x16, quad 16x16 SCXI-1334 4x64 With HV AB or matrix expansion cable. Specifications Maximum Working Voltage Maximum working voltage refers to the signal voltage plus the common-mode voltage. This chapter describes the SCXI chassis, lists what you need to get started, and describes the optional software and equipment. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 0 in. pdf) Atmos 2 Way Fitting instructions manual (UPD: 23 Nov 2022, mx/atmos-2-way. Our. If the product model does not match the picture, the product model shall prevail. com One of the following modules: – SCXI-1120 – SCXI-1120D – SCXI-1121 – SCXI-1125 – SCXI-1126 Number 1 and 2 Phillips-head screwdrivers 1/8 in. SCXI-1333 Data acquisition card, NI, SCXI-1333 Data acquisition card Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United StatesSCXI-1314 Printed Circuit Board Diagram The following illustration shows the locations of the SCA and SCB resistors, the quarter-bridge resistors, and channels 0 through 7 of the SCXI-1314 terminal block. . SCXI-1333 Board to Guide Map Circuit Board Markings Wiring Guide. Page 32 Right-click the module you want to configure and select Properties. It also describes the NI-DAQmx software relative. Refer to. It meets the demanding cooling. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ [email protected] relays that switch the resistors in and out of the input circuit to provide shunt calibration and quarter-bridge completion. SCXI-1160 SCXI-1324 48 screw. Note; All products of this site are special products, the market price has been fluctuating, specific customer service quotation shall prevail, because the product is a new product, the picture is notNote; All products of this site are special products, the market price has been fluctuating, specific customer service quotation shall prevail, because the product is a new product, the picture is notNI SCXI-1129 256-Crosspoint Relay Matrix This document lists specifications for the NI SCXI-1129 matrix module. Set the SCXI chassis address switch positions to the desired address. Refer to the following tables to determine how the circuit board corresponds to the wiring guide. Install the SCXI modules into the chassis—refer to your module/chassis documentation for instructions. SCXI -1333/1334/1336/1339 WIRING MAPS The terminal names on the circuit board differ from those on the wiring guide located on the underside of the terminal block lid. pdf ⭳ Download pdf. The following is a comprehensive list of all National Instruments part numbers that were made End-of-Life. are not included with this equipment unless listed in the above stock item description. Unscrew the four captive cover screws in the corners of the TBX-1303 terminal block and remove the cover. Since this Switch Module’s relays can switch at a maximum of 8 A at 125 Vrms, 6 A at 250 Vrms, or 5. SCXI-1160 SCXI-1324 48. All specifications are subject to change without notice. 由于大部分机载电子设备的信号数量很多,不可能将所有信号同时直接连接到资源上,必须经过继电器矩阵进行切换,继电器必须具有足够快的响应时间,能通断较大的信号,因此我们选用两块继电器矩阵模块scxi-1129和附件scxi-1333、scxi-1339,组合成合适. Conventions The following conventions are used in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. The SH1006868 cable is available in lengths of 1, 2, 5, and 10 m. com Data Acquisition and Signal Conditioning Overview Na tional Instruments SCXI terminal blocks provide a convenientSCXI Terminal Blocks DAQ and Signal Conditioning SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. In Stock Ships Today: SCXI-1332: National Instruments SCXI-1132 is a matrix terminal block : In Stock Ships Today: SCXI-1333: National Instruments SCXI-1333 is a module used to configure the SCXI-1129 as a quad 4x16 matrix: In Stock. Whether you need to measure sensors or raw signals, generate voltages or currents, monitor digital lines, or route signals with switching, SCXI provides a single, integrated. 40 m 185440-0R4 cables (Figure 7) connect the rows of adjacent terminal blocks. Migrating existing applications to the. SCXI-1333 Installation instructions manual (UPD: 03 Nov 2022, ni/scxi-1333. The SCXI-1102 also can acquire millivolt, volt, 0 to 20 mA, and 4 to 20 mA current input signals,as well as signals from RTDs when the SCXI-1581 provides excitation. Lai Wechat:17750010683 Whats app:+86 17750010683SCXI-1333: National Instruments SCXI-1333 is a module used to configure the SCXI-1129 as a quad 4x16 matrix: In Stock Ships Today: SCXI-1334: The SCXI-1334 is a National Instruments 64-Channel Terminal Block with a Maximum Working Voltage 150 V . Tabs are displayed containing attributes for different. NI offers recommended replacements or migration paths for new and existing applications for some of the affected products. Measuring Instruments. NI SCXI-1129 256-Crosspoint Relay Matrix This document lists specifications for the NI SCXI-1129 matrix module. 0. However, I see a lot of noise (+/- 0. SCXI-1129 SCXI-1333 – Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrixSCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1305 Ð BNC connectors, AC/DC coupling and signal ground referencing SCXI-1122 SCXI-1322 Ð SCXI-1124 SCXI-1325 Ð Ð SCXI-1127 SCXI-1331 Ð SCXI-1128 SCXI-1332 Ð Set up an 8 column by 4 row matrix SCXI-1129 SCXI-1333 Ð Configures SCXI-1129 as quad, 4 x 16 (2-wire). The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. When users complete a measurement with NI Software, the driver automatically uses the calibration constants to adjust the measured voltages to the correct values. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. SCXI-1129 SCXI-1333 – Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrixThe SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. From SCXI 1303, we are using 88 channels (40. To use a mixed system for Signal Conditioning the user can either purchase a mixed SCXI/PXI single source chassis from NI or use two different chassis, typically controlled from an. Yes, with matrix expansion plug. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. NI is committed to producing environmentally friendly products as part of the NI Hazardous Substance Reduction initiative, a voluntary program modeled after the EU Directive on Restriction of the Use of Certain Hazardous Substances (RoHS). TBX-1303 32-Channel Isothermal Terminal Block Installation GuideThe SCXI-1303 32-channel isothermal terminal block is a shielded board. First, on the front panel, there is a 68-pin male connector. About Us . The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. SCXI-1160 SCXI-1324 48. All specifications are subject to change without notice. com bold Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. pdf) 440 Installation instructions (UPD: 13 Feb 2023, dema/440. Thus, this setup allows the user to scan input channels from multiple modules at a rate of 333 kS/s for every DAQ device. This module is created for affordable signal conditioning of millivolt, volt, and current signals. It provides direct connectivity of signal wires to the screw terminals inside the terminal blocks. Control Unit NI SCXI-1333 Installation Instructions Manual. Test Equipment Verification requires a high-precision voltage source with at least 50 ppmThis is part 7 in our blog series about the National Instruments SCXI platform!Part 7 will discuss the remaining front-mounting SCXI terminal blocks not previously discussed in part 6. National Instruments SCXI-1359 2-Slot High Voltage Backplane Adaptor. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. Page 5 Reinstall the top cover and tighten the top cover screws. Plugs in on the top or bottom of the SCXI-1333, SCXI-1334, SCXI-1335, SCXI-1336 terminal blocks; Data Sheet ; The matrix expansion plug is a revolutionary switching accessory with which you can adjoin the NI SCXI-1129 high-density matrix to additional modules for matrix expansion. SCXI-1308 for the appropriate module, as indicated in Figure 1. Refer to the following tables to determine how the circuit board corresponds to the wiring guide. SCXI -1303 32-CHANNEL ISOTHERMAL TERMINAL BLOCK. The SCXI-1303 has a high-accuracy thermistor, cold-junction temperature sensor, and an isothermal copper plane to. 1%, 10 ppm, 1/4 W resistor across each channel to convert current to voltage. SCXI-1328 Installation Guide 2 ni. 1. Examples: 8x64, 8x128 With matrix. Terminal block for the ni scxi-1129 (10 pages) Control Unit NI SCXI-1160 Note To Users. Installation Instructions Manual. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. SCXI -1333/1334/1336/1339 WIRING MAPS The terminal names on the circuit board differ from those on the wiring guide located on the underside of the terminal block lid. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100. 40 m 185440-0R4 cables (Figure 7) connect the rows of adjacent terminal blocks. The SCXI-1338 contains a precision 249 O, 0. It is practical to mix SCXI and PXI. 343159 × 10–4, c = 1. Check the installation. TC-4353. To connect the signal to the terminal block, perform the following steps, referring to Figures 1 and 2 as necessary: 1. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Topologies 2-wire 16 × 16 matrix 2-wire 4 × 64 matrix 2-wire 8 × 32 matrix 2-wire quad 4 × 16 matrix 2-wire dual 4 × 32 matrix 2-wire dual 8 × 16 matrixThis page provides dimensional drawings for the SCXI-1333. The relay must have a fast enough response time to switch on and off large signals, so we Two relay matrix modules SCXI-1129 and accessories SCXI-1333 and SCXI-1339 are selected to form a suitable relay matrix (maximum on-off capacity 150VDC / 1A, 150Vrms / 250mA). The NI USB-9263 consists. Use the " Multiplexed CJC string " listed above for the particular SCXI module. niでは、eu rohs指令に倣って策定した有害物質削減活動の一環として、環境にやさしい製品の製造に努めています。以下の一覧表では、rohs指令に準拠することを目的として、2016年後半に販売終了を予定しているni製品の製品番号をご確認いただけます。 niでは、これらの製品の一部に対して. The SCXI-1129 module can be utilized with one of the following terminal blocks: the SCXI-1336, SCXI-1333, SCXI-1335, SCXI-1337, SCXI-1334, or SCXI-1339. NI SCXI. SCXI-1120 SCXI-1305 – BNC connectors, AC/DC coupling and ground referencing SCXI-1120D SCXI-1320 – SCXI-1126 SCXI-1327 Extends signal input range to 300 Vrms, switch configurable per channel SCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1338 Current input, 249 Ω resistor across each inputNational Instruments PXIe-4302 User Manual And Specifications (22 pages) Terminal block, 32 ch, 24-bit, 5 ks/s or 51. SCXI-1333 Board to Guide Map Circuit Board Markings Wiring Guide. Document Type . One Year Warranty. The. All specifications are. The NI SCXI-13xx front-mount terminal blocks feature direct connections to transducers at the screw terminals located within a fully shielded enclosure or at front-mounted BNC. All specifications are subject to change without notice. SCXI-1160 . National Instruments SCXI is a high-performance signal conditioning and switching platform for measurement and automation systems. shown in Figure 1. 06-20-2001 03:52 PM. However, the two standards are mechanically different (SCXI cards are larger than 3U PXI) and electrically very different. com Equipment and Other Test Requirements This section describes the equipment, software, documentation, and test conditions required for verifying the performance of your SCXI-1303 terminal block. Accessories Available for the NI SCXI-1129 Accessory Part Number NI SCXI-1333 terminal block (quad 4 × 16, 2-wire matrix) 777687-33 NI SCXI-1334 terminal block (4 × 64, 2-wire matrix) 777687-34. Because of the general-purpose nature of this terminal block, you can combine the rows and/or columns to create many different matrix configurations. "-Mike Phan "Hand carrying parts to fedex directly to make sure I get them overnight. Installation Manual And Terminal Block Specifications. Refer to the SCXI Quick Start Guide to determine the appropriate module. Then, follow the steps below: 1. In most applications, this is the most convenient grounding option. com ¥ ni. When the SCXI module is configured in parallel mode, each of the analog input lines on the DAQ board cabled to the SCXI chassis is routed directly to a single input line on the connected SCXI module. Part Number: 182245B-01, 182245C-01, 182245D-01, 195700A-01, 195700B-01, 185700B-01, 185700A-01. operating properly, and set up multichassis systems. User Manual. . Refer to the following tables to determine how the circuit board corresponds to the wiring guide. 2. ). There are still some cards that are sold with the standard PXI connector option so that they can control the SCXI portion of a PXI/SCXI combination Chassis : PXI-6221 (P/N: 779113-01) PXI. Show all National Instruments Industrial Electrical manuals . 75 m 185440-0R75 Matrix expansion Use with the SCXI-1333,SCXI-1334, SCXI-1335, and 778364-01 plug (Figure 8) SCXI-1336 to connect the columns of adjacent terminal blocks. XP1200i. Topologies 2-wire 16 × 16 matrix 2-wire 4 × 64 matrix 2-wire 8 × 32 matrix 2-wire quad 4 × 16 matrix 2-wire dual 4 × 32 matrix 2-wire dual 8 × 16 matrixSCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1305 Ð BNC connectors, AC/DC coupling and signal ground referencing SCXI-1122 SCXI-1322 Ð SCXI-1124 SCXI-1325 Ð Ð SCXI-1127 SCXI-1331 Ð SCXI-1128 SCXI-1332 Ð Set up an 8 column by 4 row matrix SCXI-1129 SCXI-1333 Ð Configures SCXI-1129 as quad, 4 x 16 (2-wire). In Figure 4, all switches are shown in the off position. . 1 68-Pin Male Connector, TO. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politicsSCXI-1120 SCXI-1305 – BNC connectors, AC/DC coupling and ground referencing SCXI-1120D SCXI-1320 – SCXI-1126 SCXI-1327 Extends signal input range to 300 Vrms, switch configurable per channel SCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1338 Current input, 249 Ω resistor across each inputSCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-012. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This guide describes how to install and use the SCXI-1303 terminal block with SCXI-1102, SCXI-1102B, SCXI-1102C,. Connect the terminal block to the module front connector as explained in the Installation section. 32. When used with the SCXI-1102/B/C, this terminal block provides a high-impedance path (10 M Ohm) from the negative input terminal to ground. 21. The following is a comprehensive list of all National Instruments part numbers that were made End-of-Life. I connected a different SCXI-1000 mainframe with scxi 1600 and scxi-1303 modules. com Data Acquisition and Signal Conditioning Overview Na tional Instruments SCXI terminal blocks provide a convenient method for connecting and. If you are new to our. 40 m. Solution The driver needed for the SCXI hardware is NI-DAQmx. Investment Highlights. This page provides dimensional drawings for the SCXI-1333. Each channel is independently configurable through jumpers. 4. Topologies 2-wire 16 × 16 matrix 2-wire 4 × 64 matrix 2-wire 8 × 32 matrix 2-wire quad 4 × 16 matrix 2-wire dual 4 × 32 matrix 2-wire dual 8 × 16 matrixNational Instruments SCXI-1356. The National Instruments SCXI-1303 terminal block provides a convenient method for connecting and disconnect signals to your system. Brand: NI. The SCXI-1333 is a general-purpose terminal block that gives you access to all row and column connections. Examples: 4×128, 4×256, and so on. SCXI-1120 SCXI-1305 – BNC connectors, AC/DC coupling and ground referencing SCXI-1120D SCXI-1320 – SCXI-1126 SCXI-1327 Extends signal input range to 300 Vrms, switch configurable per channel SCXI-1328 Isothermal, high-accuracy design for thermocouples SCXI-1338 Current input, 249 Ω resistor across each inputSpecifications: 1595/1595447-elpro_x. You must also connect the SCANADVD signal from the SCXI-1333 terminal block to your DMM external trigger input. Make sure the E/M/X Series DAQ device is recognized by the operating system, is found in MAX, and passes the resource test. Table 1. Because of the general-purpose nature of this terminal block, you can combine the rows and/or columns to create many different matrix configurations. This document describes the components, installation, and configuration. com terminal block. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. The National Instruments NI SCXI-1303 has an extremely precise thermistor cold-junction. ni scxi-1129 256クロスポイント リレーマトリクス このドキュメントには、ni scxi-1129マトリクスモジュールの仕様が記載されていま す。すべての仕様は、通知なしに変更されることがあります。 トポロジ 2線式16 × 16マトリクス 2線式4 × 64マトリクス SCXI-1328 3 Isothermal, high-accuracy design for thermocouples SCXI-1305 Ð BNC connectors, AC/DC coupling and signal ground referencing SCXI-1122 SCXI-1322 3 Ð SCXI-1124 SCXI-1325 Ð Ð SCXI-1127 SCXI-1331 3 Ð SCXI-1128 SCXI-1332 Ð Set up an 8 column by 4 row matrix SCXI-1129 SCXI-1333 Ð Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrix You can use the SCXI-1333 with the SCXI-1129 to create four, 4 × 16 matrices. SCXI-1333 NI module SCXI-1333 NI module Module Clips Drive controller servo motor Contact: Mr. The terminal block works with the use of matrix expansion plugs for instant row expansion via column connection and requires no external wiring. The NI SCXI 1001 can also synchronize the timing between the DAQ device and each module. Page 1 SCXI SCXI-1121 User Manual SCXI-1121 User Manual April 2010 373143A-01. This terminal block provides screw terminals for connection to the SCXI-1127 and SCXI-1128 lines and a cold-junction compensation sensor. 04-24-2009 02:24 AM. The SCXI-1120 module is designed for low-cost signal conditioning of. 40 m 185440-0R4 cables (Figure 7) connect the rows of adjacent terminal blocks. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. Within the SCXI chassis, identify the appropriate SCXI module to connect to the cable adapter. This document contains information about the NI-DAQmx driver software, which you canThis document explains how to install and configure SCXI signal conditioning modules in SCXI-1000, SCXI-1001, SCXI-1000DC, or PXI/SCXI combination chassis, confirm the module and chassis are. You can also choose either the TC-2095 or BNC-2095 rack-mount terminal blocks for minithermocouple. Up to 50% Off MSRP. SCXI-1112 module and contains information concerning its installation and operation. Investment Highlights.